Description:
The SDR-120 series is a DIN rail-mounted switch power supply,is widely used in industrial control, automation equipment, instrumentation, communication devices, and LED lighting applications, among others. Here is an overview of its key features and specifications:
Model Designation: Within the SDR-120 series, specific models are identified according to their output voltage. For instance, SDR-120-24 denotes a 24V output, while SDR-120-12, SDR-120-36, and SDR-120-48 correspond to 12V, 36V, and 48V output voltages, respectively.
Output Power: Rated output power is 120W.
Input Voltage: Supports a wide range AC input, typically from 85VAC to 264VAC,adapting varying global mains voltage standards.
Efficiency: Offers high efficiency, usually above 78%, reducing energy consumption and operational costs.
Protection Features: Equipped with overload, short circuit, and over-temperature protection mechanisms to ensure the safety of both the power supply and the system it supports.
PFC: Some models include Active Power Factor Correction (PFC), enhancing energy utilization, minimizing grid pollution, and complying with stringent EMC requirements.
Size & Installation: Designed as a slim profile for easy installation in space-constrained control cabinets, utilizing standard DIN rail mounting.
Certifications: Carries multiple international safety certifications such as CE, assuring product quality and safety.
Power supply for industrial automation control systems.
Powering instruments, sensors, and actuators.
LED lighting drive power solutions.
Power needs in telecommunications and networking equipment.
Power requirements in security and surveillance systems.
Specifications:
Model | SDR-120-12 | SDR-120-24 | SDR-120-48 | |
Output | DC Voltage | 12V | 24V | 48V |
Current Range | 0-10A | 0-5A | 0-2.5A | |
Rated Power | 120W | 120W | 120W | |
Ripple Noise(Max) | 100mVp-p | 120mVp-p | 150mVp-p | |
Voltage Adj.Range | 12-14V | 24-28V | 48-55V | |
Voltage Tolerance | ±1.0% | ±1.0% | ±1.0% | |
Line Regulation | ±0.5% | ±0.5% | ±0.5% | |
Load Regulation | ±1.0% | ±1.0% | ±1.0% | |
Set up,Rise time | 1500ms,60ms/230VAC 3000ms,60ms/115VAC(full load) | |||
Hold up Time | 20ms/230VAC 20ms/115VAC(full load) | |||
Input | Voltage Range | 88 ~264VAC 124~370VDC[DC input operation possible by connecting AC/L(+),AC/N(-)] | ||
Frequency | 47 ~ 63Hz | |||
Efficiency | 85% | 88% | 90% | |
AC Current | 1.4A/115VAC 0.85A/230VAC | |||
Inrush Curent | 30A/115VAC 50A/230VAC | |||
Leakage Current | <1mA / 240VAC | |||
Protection | Overload | Normally works within 110~150% rated output power for more than 3 seconds and then shut down o/p voltage,re-power on to recover | ||
150~170%rated power,constant current limiting with auto-recovery within 3 seconds,and then shut down o/p voltage after 3 seconds,re-power on to recover | ||||
Over Voltage | 14-17V | 29-33V | 56-65V | |
Protection type : Shut down o/p voltahe, re-power on to recover | ||||
Over Temperature | Shut down o/p voltage,re-power on to receover after temperature goes down | |||
Environment | Working Temperature | -30~ +70℃ (Refer to derating curve as datasheet from SMUN) | ||
Working Humidity | 20 ~ 95% RH non-condensing | |||
Storage Temp.Humidity | -40 ~ +85℃, 10 ~ 95% RH | |||
Temp.Coefficient | ±0.03%/℃ (0 ~ 50℃) | |||
Vibration | Component:10~500Hz,2G 10min./1 cycle,60min. each along X,Y,Z axes; Mounting: Compliance IEC60068-2-6 | |||
Safety | Safety Standards | Ul508, TUV BS EN/EN62368-1, EAC TP TC 004, BSMI CNS14336-1 approved;(meet BS EN/EN60204-1) | ||
Withstand Voltage | I/P-O/P:2KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC/25℃/70% RH | |||
EMC Emission | Compliance to BS EN/EN55032(CISPR32), BS EN/EN61000-3-2,EAC TP TC 020, CNS13438 Class A | |||
EMC Immunity | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11,BS EN/EN55024, BS EN/EN61000-6-2(BS EN/EN50082-2), heavy industry level, criteria A,EAC TP TC 020 | |||
Others | MTBF | 292.1k hrs MIL-HDBK-217F(25℃) | ||
Dimension | 40*125.2*113.5mm (L*W*H) | |||
Packing | 0.67Kg; 28pcs/15.3Kg/1.22CUFT | |||
Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line ragulation and load regulation. 4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power.In case the adjacent device is a heat soure, 15mm clearance is recommended 6. Derating may be needed under low input voltage. Please check the derating curve for more details. 7.Please contact with SMUN customer service for more details. |
Home About Us Power Supply Service&Support Solution Blogs Contact Us Privacy Policy