Description:
LRS-60 series switch-mode power supply, an industry-leading solution designed to provide reliable, efficient, and versatile power management for a wide array of applications. Here's a comprehensive overview of this exceptional product, highlighting its key features, benefits, and suitability for diverse buyer needs
Feature:
1.High-Efficiency Conversion:
The LRS-60 series employs advanced Pulse Width Modulation (PWM) technology, achieving conversion efficiencies surpassing 90%, contributing to reduced energy consumption and operating expenses.
2.Wide Input Voltage Range:
Supports universal AC input voltage ranges, such as 85 to 264VAC, or DC input ranges like 120 to 370VDC, ensuring reliable operation across diverse global power grids.
3.Diverse Output Voltages:
Offers multiple fixed-output voltage versions, including LRS-60-12 (12V output), LRS-60-24 (24V output), and LRS-60-48 (48V output), catering to varying voltage requirements of different devices.
4.Precision Regulation:
Incorporates precise voltage regulation circuitry, ensuring output voltage remains steady under load variations, with excellent load regulation, providing consistent power supply to load equipment.
5.Comprehensive Protection:
Equipped with built-in overcurrent, short-circuit, overvoltage, undervoltage, and over load protections, ensuring timely disconnection of power in abnormal conditions, safeguarding both the power supply and connected load devices.
6.Efficient Cooling & Robust Construction:
Features effective cooling designs and premium materials to maintain low operating temperatures even at full load, prolonging the unit's lifespan. The enclosure is structurally robust, offering good mechanical protection.
7.International Approvals:
Conforms to CE, RoHS, and other international safety and environmental standards, passing relevant electromagnetic compatibility (EMC) tests, ensuring global market compliance.
Applications:
The LRS-60 series is widely used across various sectors, including:
LED Lighting: Providing constant voltage and current for indoor and outdoor LED fixtures, signage, and architectural lighting.
Industrial Automation: Powering PLCs, motors, sensors, and control systems in manufacturing and process control environments.
Security Systems: Supplying reliable power to CCTV cameras, access control devices, and security alarms.
Telecommunications: Supporting base stations, routers, switches, and other network infrastructure equipment.
Medical Equipment: Ensuring stable power for diagnostic and monitoring devices, patient care equipment, and laboratory instruments.
Transportation: Used in vehicle charging systems, onboard electronics, and signaling equipment.
Model | LRS-60-12 | LRS-60-15 | LRS-60-24 | LRS-60-36 | LRS-60-48 | |
Output | DC Voltage | 12V | 15V | 24V | 36V | 48V |
Current Range | 0-5A | 0-4A | 0-2.5A | 0-1.67A | 0-1.25A | |
Rated Power | 60W | 60W | 60W | 60.12W | 60W | |
Ripple Noise(Max) | 120mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
Voltage Adj.Range | 10.8~13.2V | 13.5~16.5V | 21.6~26.4V | 32.4~39.6V | 43.2~52.8V | |
Voltage Tolerance | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Load Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Set up,Rise time | 1000ms,30ms/230VAC 2000ms,30ms/115VAC(full load) | |||||
Hold up Time | 30ms/230VAC 12ms/115VAC(full load) | |||||
Input | Voltage Range | 85 ~264VAC 120~373VDC | ||||
Frequency | 47 ~ 63Hz | |||||
Efficiency | 86% | 86% | 88% | 89% | 90% | |
AC Current | 0.95A/115VAC 0.56A/230VAC | |||||
Inrush Curent | COLD START: 45A/230VAC | |||||
Leakage Current | <0.75mA / 240VAC | |||||
Protection | Overload | 110 ~ 150% rated output power | ||||
Protection tye:Hiccup mode,recovers automatically after fault condition is removed | ||||||
Over Voltage | 13.8~16.2V | 18.8~21.8V | 27.6~32.4V | 41.4~48.6V | 55.2~64.8V | |
Protection type : Shut off o/p voltage, re-power on to recover | ||||||
Environment | Working Temperature | -10 ~ +70℃ (Refer to derating curve as datasheet from SMUN) | ||||
Working Humidity | 20 ~ 90% RH non-condensing | |||||
Storage Temp.Humidity | -45 ~ +85℃, 20 ~ 95% RH non-condensing | |||||
Temp.Coefficient | ±0.03%/℃ (0 ~ 50℃) | |||||
Vibration | 10~500Hz,2G 10 min/1 cycle,60min.each X Y Z axes | |||||
Safety | Safety Standards | GB4943.1,EN60950.1 Approved | ||||
Withstand Voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/25℃/70% RH | |||||
EMC Emission | EN61000-3-2:2014/EN61000-3-3:2013 | |||||
EMC Immunity | EN 55032:2015/EN55035:2017/60950-1 | |||||
Others | MTBF | ≥720.6K hrs MIL-HDBK-217F(25℃) | ||||
Dimension | 99*98*30mm (L*W*H) | |||||
Packing | 0.23Kg; 60pcs/14.8Kg/43*23*33mm/CTN | |||||
Note | 1.All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25℃ of ambient temperature. 2.Ripple noise are measured at 20MHz of bandwidth by using a 12"twisted pair-wire terminated with a 0.1uf and 47uf parallel capacitors. 3.Tolerance includes set up tolerance,line regulation and load regulation. 4.Derating output is required under low input voltage.Please refer to derating curve for details. 5.The power supply should be considered as a part of the components in the system.All EMC tests will test samples on a metal iron plate with a thickness of 1mm,a length of 360mm and width of 36mm. 6.Please contact with SMUN customer service for more details. |