Products

Home » Products » Switching Power Supply » LED Driver » SMV-30 Constant Voltage 30W 12V/15V/24V/36V/48V Power LED Driver

Product Category

loading

Share to:
sharethis sharing button

SMV-30 Constant Voltage 30W 12V/15V/24V/36V/48V Power LED Driver

Availability:
Quantity:
  • SMV-30

  • SMUN

Description

 

SMV-30 is a 30W industrial AC/DC power supply featuring the outstanding to operate under high humid,dusty,oily,and high-vibration harsh environment.The entire series is housed with the aluminum case and fully potted with hear-conducted silicone.Thanks to state-of-the-art design,the working efficiency up to 85%,enabling SMV-30 perfectly work between -10℃ and +60℃ under free air convection.The design of metal housing and IP67/IP65 ingress protection level allows this series to fit both indoor and outdoor applications.

 

Applications

 

Outdoor telecommunication equipment

Outdoor electronic signage and billboard

Petroleum plant or mine shaft facility

LED street lighting

LED high-bay lighting

Packing space lighting

LED fishing lamp

LED greenhouse lighting

 

Specifications

Model SMV-30-12 SMV-30-15 SMV-30-24 SMV-30-36 SMV-30-48
Output DC voltage 12V 15V 24V 36V 48V
Rated current 2.5A 2A 1.25A 0.84A 0.63A
Current range 0 ~ 2.5A 0-2.0A 0-1.25A 0-0.84A 0-0.63A
Rated power 30W 30W 30W 30W 30W
Ripple&noise 50mVp-p 50mVp-p 80mVp-p 100mVp-p 100mVp-p
Voltage tolerance ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
Line regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Set up,rise time 200ms,50ms,30ms
Hold up time(Typ.) 30ms/230VAC
Input Voltage range 85~264VAC or 120~373VDC
Frequency 47 ~ 63Hz
Efficiency 75% 80% 82% 82% 85%
AC current 0.5A/230V
Inrush current Cold start: 45A/230V
Leakage current <0.5mA/240VAC
Protection Overload Rated output power 105%~135% start overload protection
Protection type:hiccup mode,auto-recovery after fault condition is removed
Over voltage Rater output power 135%~150% start over voltage protection
Protection type:Shut down o/p voltage, re-power on to recover
Over temperature When temperature of transistor inner node is over 105℃,start over temperature protection
Protection type:Shut down o/p voltage, re-power on to recover
Environment Working temperature -10℃~+60℃
Working humidity 20-90%RH
Storage temp,humidity -20~+85℃,20%-90%RH
Temp.coefficient ±0.03%℃(0-50℃)
Vibration 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
Safety
&
EMC
Safety standards Compliance to:CE and GB4943.1 safety standards
Withstand voltage I/P-O/P:1.5KVAC 1minute I/P-FG:1.5KVAC 1minute O/P-PG:0.5KVAC 1minute
Isolation resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC emission EN61000-3-2:2014/EN61000-3-3:2013
EMC immunity EN 55032:2015/EN55035:2017/60950-1
Others MTBF ≥327.9K hrs MIL-HDBK-217F(25℃)
Size L222*W30*H20mm
Packing 0.25KG
Note 1. All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25℃ of ambient temperature.
2. Ripple&noise are measured at 20MHz of bandwidth by using a 12 "twisted pair -wire terminated with a 0.1uf and 47uf parallel capacitors.
3. Tolerance:includes set up tolerance,line regulation and load regulation.
4. Derating output is required under low input voltage. Please refer to the derating curve for details.
5. The power supply should be considered as a part of the components in the system. All EMC tests will test the test samples on a metal iron plate with a thickness of 1mm, a length of 360mm * width of 360mm.


Previous: 
Next: 

Contact Us

 No. 5, Zhengshun West Road, Xiangyang Industrial Zone, Liushi,Yueqing,Zhejiang,China,325604
+86-13868370609 
+86-0577-62657774 

Quick Links

Quick Links

Copyright © 2024 Zhejiang Ximeng Electronic Technology Co., Ltd. Support by  Leadong   Sitemap
Contact us