Products

Home » Products » Switching Power Supply » Din Rail Power Supply » DR-60 60W Din Rail Power Supply

Product Category

loading

Share to:
sharethis sharing button

DR-60 60W Din Rail Power Supply

Availability:
Quantity:
  • DR-60

  • SMUN

Description:

The DR-60 is a commonly used rail-mounted switch mode power supply, extensively applied in fields such as industrial automation, electrical control cabinets, LED lighting, and security surveillance. Below is a general introduction and overview of its features:

Features:

  • Universal AC input/Full range

  • Protections:Short circuit/Overload/Over voltage

  • Cooling by free air convection

  • Can be installed on DIN RAIL TS-35/7.5 or 15

  • LED indicator for power on

  • No load power consumption<0.75W

  • 100% full load burn-in test

  • 2 years warranty

Applications:

  • Industrial Automation: Powers PLCs, sensors, actuators, and other control components.

  • LED Lighting: Supplies stable power to small to medium-sized LED lighting fixtures.

  • Security Surveillance: Powers CCTV cameras, access control systems, and other security equipment.

  • Communication Equipment: Suitable for small-scale switches, routers, and the like.

  • Instrumentation: Provides power support for various measuring and testing equipment.



Specifications:

Model DR-60-12 DR-60-24 DR-60-48
Output DC Voltage 12V 24V 48V
Current Range 0-5A 0-2.5A 0-1.25A
Rated Power 60W 60W 60W
Ripple Noise(Max) 80mVp-p 100mVp-p 120mVp-p
Voltage Adj.Range 12-15V 24-30V 48-55V
Voltage Tolerance ±1.5% ±1.0% ±1.0%
Line Regulation ±0.5% ±0.5% ±0.5%
Load Regulation ±1.5% ±1.0% ±1.0%
Set up,Rise time 500ms,30ms/230VAC   1000ms,30ms/115VAC(full load)
Hold up Time 60ms/230VAC     12ms/115VAC(full load)
Input Voltage Range 85 ~264VAC    120~370VDC
Frequency 47 ~ 63Hz
Efficiency 77% 81% 83%
AC Current 0.55A/115VAC    4A/230VAC
Inrush Curent 40A/230VAC
Leakage Current <1mA / 240VAC
Protection Overload 105 ~ 130% rated output power
Protection tye:Constant current limiting,recovers automatically after fault condition is removed
Over Voltage 14-17V 29-33V 56-65V
Protection type : Shut off o/p voltage, re-power on to recover
Environment Working Temperature -10~ +60℃ (Refer to derating curve as datasheet from SMUN)
Working Humidity 20 ~ 90% RH non-condensing
Storage Temp.Humidity -20 ~ +85℃, 10 ~ 95% RH
Temp.Coefficient ±0.03%/℃ (0 ~ 50℃)
Vibration Component:10~500Hz,2G 10min./1 cycle,60min. each along X,Y,Z axes
Safety
Safety Standards CE and GB4943.1 Safety standard
Withstand Voltage I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC/25℃/70% RH
EMC Emission Compliance to EN61000-3-2:2014/EN61000-3-3:2013
EMC Immunity Compliance to EN55032:2015/EN55035:2017/60950-1
Others MTBF ≥327.9K hrs MIL-HDBK-217F(25℃)
Dimension 93*78*56mm (L*W*H)
Packing 0.25Kg; 60pcs/15Kg
Note

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 

3. Tolerance : includes set up tolerance, line ragulation and load regulation. 

4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 

5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power.In case the adjacent device is a heat soure, 15mm clearance is recommended

6. Derating may be needed under low input voltage. Please check the derating curve for more details.

7.Please contact with SMUN customer service for more details.



Previous: 
Next: 

Contact Us

 No. 5, Zhengshun West Road, Xiangyang Industrial Zone, Liushi,Yueqing,Zhejiang,China,325604
+86-13868370609 
+86-0577-62657774 

Quick Links

Quick Links

Copyright © 2024 Zhejiang Ximeng Electronic Technology Co., Ltd. Support by  Leadong   Sitemap
Contact us