MDR-40
SMUN
Description:
The MDR-40 is a high-performance DIN rail-mounted switch mode power supply widely utilized in industrial automation, instrumentation, communication systems, LED lighting, and security surveillance applications. As a representative product in the 40-watt power category, the MDR-40 series offers a stable and efficient DC power solution.
Output Power: Rated power is 40 watts, catering to the needs of most medium to low-power devices.
Voltage and Current: Depending on the model, it provides various output voltage options, such as 5V, 12V, 24V, 48V, etc., with the current automatically adjusted to ensure the total output power does not exceed 40W. For instance, the MDR-40-48 model outputs 48V at 0.83A.
DIN Rail Mounting: Incorporates a standard DIN rail mounting design (usually compatible with TS35/7.5 or TS35/15 profiles), allowing for swift integration into electrical control cabinets.
Ultra-Slim Profile: The MDR-40 is designed with space-saving in mind, featuring a slim construction ideal for confined installation spaces.
Optimized Cooling: Despite its high power density, efficient heat dissipation is ensured through optimized thermal design, promoting long-term reliability and stability.
Plastic Housing: Constructed from flame-retardant, high-temperature-resistant plastic materials, providing a lightweight yet safe enclosure suitable for industrial environments.
Energy Efficiency: Boasts high conversion efficiency, reducing energy consumption, with some models potentially equipped with Active Power Factor Correction (PFC) to further enhance power usage efficiency.
Wide Input Voltage Range: Compatible with global voltage standards, with an input voltage range typically spanning from 85VAC to 264VAC, adapting to different grid conditions worldwide.
Comprehensive Protection:Built-in overvoltage, overcurrent, short-circuit protection, and over-temperature protection mechanisms,safeguarding both the power supply and connected devices.
Longevity Design: Utilizes high-quality components and is designed with excellent electromagnetic compatibility (EMC), ensuring prolonged stable operation, with some manufacturers even offering lifetime warranty services.
Industrial Automation: Powers PLCs, HMI interfaces, sensors, and more.
Security Systems: Suited for CCTV cameras, access control systems, etc.
LED Lighting: Supplies stable power to LED luminaires.
Communication Equipment: Supports power needs for small-scale network switches, routers, etc.
Instrumentation & Control: Powers a variety of measuring instruments and control panels.
Specifications:
Model | MDR-40-12 | MDR-40-24 | MDR-40-48 | |
Output | DC Voltage | 12V | 24V | 48V |
Current Range | 0-3.4A | 0-1.7A | 0-0.83A | |
Rated Power | 40.8W | 40.8W | 39.8W | |
Ripple Noise(Max) | 120mVp-p | 150mVp-p | 180mVp-p | |
Voltage Adj.Range | 10.8~13.2V | 21.6~26.4V | 43.2~52.8V | |
Voltage Tolerance | ±1.0% | ±1.0% | ±1.0% | |
Line Regulation | ±1.0% | ±1.0% | ±0.2% | |
Load Regulation | ±1.0% | ±1.0% | ±0.5% | |
Set up,Rise time | 500ms,30ms/230VAC 1000ms,30ms/115VAC(full load) | |||
Hold up Time | 50ms/230VAC 20ms/115VAC(full load) | |||
Input | Voltage Range | 85 ~264VAC 124~370VDC | ||
Frequency | 47 ~ 63Hz | |||
Efficiency | 76% | 80% | 84% | |
AC Current | 0.55A/115VAC 0.35A/230VAC | |||
Inrush Curent | 20A/115VAC 40A/230VAC | |||
Leakage Current | <1mA / 240VAC | |||
Protection | Overload | 105~160% rated output power | ||
Protection type:hiccup mode,recovers automatically after faul condition is removed. | ||||
Over Voltage | 13.8~16.2V | 28.5~33.8V | 41.4~48.6V | |
Protection type : Shut down o/p voltahe, recovers automatically after fault condition is removed | ||||
Function | DC OK Active Signal(Max.) | 9~13.5V/40mA | 18~27V/20mA | 41~54V/10mA |
Environment | Working Temperature | -20~ +70℃ (Refer to derating curve as datasheet from SMUN) | ||
Working Humidity | 20 ~ 90% RH non-condensing | |||
Storage Temp.Humidity | -20 ~ +85℃, 10 ~ 90% RH | |||
Temp.Coefficient | ±0.03%/℃ (0 ~ 50℃) | |||
Vibration | Component:10~500Hz,2G 10min./1 cycle,60min. each along X,Y,Z axes; Mounting: Compliance IEC60068-2-6 | |||
Safety | Safety Standards | Comply with CE and GB4943.1 safety standards | ||
Withstand Voltage | I/P-O/P:2KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC/25℃/70% RH | |||
EMC Emission | EN61000-3-2:2014/EN61000-3-3:2013 | |||
EMC Immunity | EN55032:2015/EN55035:2017/60950-1 | |||
Others | MTBF | >327.9k hrs MIL-HDBK-217F(25℃) | ||
Dimension | 40*90*100mm (L*W*H) | |||
Packing | 0.25Kg | |||
Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The output needs to be reduced under the condition of low input voltage, refer to the derating curve chart for details. 5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may increase of the set up time. 6.Please contact with SMUN customer service for more details. |
Description:
The MDR-40 is a high-performance DIN rail-mounted switch mode power supply widely utilized in industrial automation, instrumentation, communication systems, LED lighting, and security surveillance applications. As a representative product in the 40-watt power category, the MDR-40 series offers a stable and efficient DC power solution.
Output Power: Rated power is 40 watts, catering to the needs of most medium to low-power devices.
Voltage and Current: Depending on the model, it provides various output voltage options, such as 5V, 12V, 24V, 48V, etc., with the current automatically adjusted to ensure the total output power does not exceed 40W. For instance, the MDR-40-48 model outputs 48V at 0.83A.
DIN Rail Mounting: Incorporates a standard DIN rail mounting design (usually compatible with TS35/7.5 or TS35/15 profiles), allowing for swift integration into electrical control cabinets.
Ultra-Slim Profile: The MDR-40 is designed with space-saving in mind, featuring a slim construction ideal for confined installation spaces.
Optimized Cooling: Despite its high power density, efficient heat dissipation is ensured through optimized thermal design, promoting long-term reliability and stability.
Plastic Housing: Constructed from flame-retardant, high-temperature-resistant plastic materials, providing a lightweight yet safe enclosure suitable for industrial environments.
Energy Efficiency: Boasts high conversion efficiency, reducing energy consumption, with some models potentially equipped with Active Power Factor Correction (PFC) to further enhance power usage efficiency.
Wide Input Voltage Range: Compatible with global voltage standards, with an input voltage range typically spanning from 85VAC to 264VAC, adapting to different grid conditions worldwide.
Comprehensive Protection:Built-in overvoltage, overcurrent, short-circuit protection, and over-temperature protection mechanisms,safeguarding both the power supply and connected devices.
Longevity Design: Utilizes high-quality components and is designed with excellent electromagnetic compatibility (EMC), ensuring prolonged stable operation, with some manufacturers even offering lifetime warranty services.
Industrial Automation: Powers PLCs, HMI interfaces, sensors, and more.
Security Systems: Suited for CCTV cameras, access control systems, etc.
LED Lighting: Supplies stable power to LED luminaires.
Communication Equipment: Supports power needs for small-scale network switches, routers, etc.
Instrumentation & Control: Powers a variety of measuring instruments and control panels.
Specifications:
Model | MDR-40-12 | MDR-40-24 | MDR-40-48 | |
Output | DC Voltage | 12V | 24V | 48V |
Current Range | 0-3.4A | 0-1.7A | 0-0.83A | |
Rated Power | 40.8W | 40.8W | 39.8W | |
Ripple Noise(Max) | 120mVp-p | 150mVp-p | 180mVp-p | |
Voltage Adj.Range | 10.8~13.2V | 21.6~26.4V | 43.2~52.8V | |
Voltage Tolerance | ±1.0% | ±1.0% | ±1.0% | |
Line Regulation | ±1.0% | ±1.0% | ±0.2% | |
Load Regulation | ±1.0% | ±1.0% | ±0.5% | |
Set up,Rise time | 500ms,30ms/230VAC 1000ms,30ms/115VAC(full load) | |||
Hold up Time | 50ms/230VAC 20ms/115VAC(full load) | |||
Input | Voltage Range | 85 ~264VAC 124~370VDC | ||
Frequency | 47 ~ 63Hz | |||
Efficiency | 76% | 80% | 84% | |
AC Current | 0.55A/115VAC 0.35A/230VAC | |||
Inrush Curent | 20A/115VAC 40A/230VAC | |||
Leakage Current | <1mA / 240VAC | |||
Protection | Overload | 105~160% rated output power | ||
Protection type:hiccup mode,recovers automatically after faul condition is removed. | ||||
Over Voltage | 13.8~16.2V | 28.5~33.8V | 41.4~48.6V | |
Protection type : Shut down o/p voltahe, recovers automatically after fault condition is removed | ||||
Function | DC OK Active Signal(Max.) | 9~13.5V/40mA | 18~27V/20mA | 41~54V/10mA |
Environment | Working Temperature | -20~ +70℃ (Refer to derating curve as datasheet from SMUN) | ||
Working Humidity | 20 ~ 90% RH non-condensing | |||
Storage Temp.Humidity | -20 ~ +85℃, 10 ~ 90% RH | |||
Temp.Coefficient | ±0.03%/℃ (0 ~ 50℃) | |||
Vibration | Component:10~500Hz,2G 10min./1 cycle,60min. each along X,Y,Z axes; Mounting: Compliance IEC60068-2-6 | |||
Safety | Safety Standards | Comply with CE and GB4943.1 safety standards | ||
Withstand Voltage | I/P-O/P:2KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC/25℃/70% RH | |||
EMC Emission | EN61000-3-2:2014/EN61000-3-3:2013 | |||
EMC Immunity | EN55032:2015/EN55035:2017/60950-1 | |||
Others | MTBF | >327.9k hrs MIL-HDBK-217F(25℃) | ||
Dimension | 40*90*100mm (L*W*H) | |||
Packing | 0.25Kg | |||
Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The output needs to be reduced under the condition of low input voltage, refer to the derating curve chart for details. 5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may increase of the set up time. 6.Please contact with SMUN customer service for more details. |