  • MDR-60

  • SMUN

Description:


MDR-60 is a meticulously designed DIN rail-mounted switch mode power supply primarily aimed at industrial and commercial applications, providing users with an efficient and reliable DC power solution.

Features:

  • Rated Power: MDR-60 offers an output power of 60 watts, catering to the power demands of higher wattage equipment.

  • Input Voltage Range: Universally supports a wide range of AC input voltages, typically from 85VAC to 264VAC, ensuring stable operation across varied voltage environments globally.

  • Flexible Output Configurations: Depending on the model, the MDR-60 series can deliver multiple standard DC output voltages such as 5V, 12V, 24V, 48V, and more, tailored to different application requirements. For instance, the MDR-60-24 supplies 24V DC, with the current automatically adjusted based on the power output.

  • Efficiency and Energy Savings: This series commonly boasts high conversion efficiency, often exceeding 90%, effectively reducing operating costs and heat generation. Some models may incorporate Active Power Factor Correction (PFC) for enhanced grid efficiency.

  • Protection Features: Equipped with comprehensive safety protections, including Overvoltage Protection (OVP), Overcurrent Protection (OCP), Short Circuit Protection (SCP), and Over-Temperature Protection (OTP), safeguarding both the power supply and connected devices against damage.

  • Installation Method: Utilizes standard DIN rail mounting (e.g., TS35/7.5 or TS35/15 profiles), facilitating easy integration into existing control cabinets or distribution boards.

  • Mechanical Design: Features a compact and ultra-slim design, ideal for installation in space-constrained environments. The casing is made from flame-retardant, high-temperature-resistant engineering plastics, ensuring safety and reliability over extended use.

  • Electromagnetic Compatibility (EMC): Compliant with international EMC standards, ensuring stable operation in various complex electromagnetic environments and minimizing interference to other equipment.


Applications:

  • Industrial Automation: Powers PLCs, servo drives, sensors, and other industrial control devices.

  • LED Lighting: Serves as a dependable power source for LED strips, panel lights, and other lighting systems.

  • Security Surveillance: Meets the power needs of CCTV cameras, access control systems, and other security equipment.

  • Telecommunications & Networking: Provides stable power for network switches, routers, wireless access points, and more.

  • Instrumentation & Control: Supplies DC power to various measuring instruments and control systems.



Specifications:

Model MDR-60-12 MDR-60-24 MDR-60-48
Output DC Voltage 12V 24V 48V
Current Range 0-5A 0-2.5A 0-1.25A
Rated Power 60W 60W 60W
Ripple Noise(Max) 120mVp-p 150mVp-p 180mVp-p
Voltage Adj.Range 10.8~13.2V 21.6~26.4V 43.2~52.8V
Voltage Tolerance ±1.0% ±1.0% ±1.0%
Line Regulation ±1.0% ±1.0% ±0.2%
Load Regulation ±1.0% ±1.0% ±0.5%
Set up,Rise time 500ms,30ms/230VAC   1000ms,30ms/115VAC(full load)
Hold up Time 50ms/230VAC     20ms/115VAC(full load)
Input Voltage Range 85 ~264VAC    124~370VDC
Frequency 47 ~ 63Hz
Efficiency 76% 80% 84%
AC Current 0.55A/115VAC    0.35A/230VAC
Inrush Curent 20A/115VAC 40A/230VAC
Leakage Current <1mA / 240VAC
Protection Overload 105~160% rated output power
Protection type:hiccup mode,recovers automatically after faul condition is removed.
Over Voltage 13.8~16.2V 28.5~33.8V 41.4~48.6V
Protection type : Shut down o/p voltahe, recovers automatically after fault condition is removed
Function DC OK Active Signal(Max.) 9~13.5V/40mA
18~27V/20mA 41~54V/10mA
Environment Working Temperature -20~ +70℃ (Refer to derating curve as datasheet from SMUN)
Working Humidity 20 ~ 90% RH non-condensing
Storage Temp.Humidity -20 ~ +85℃, 10 ~ 90% RH
Temp.Coefficient ±0.03%/℃ (0 ~ 50℃)
Vibration Component:10~500Hz,2G 10min./1 cycle,60min. each along X,Y,Z axes; Mounting: Compliance IEC60068-2-6
Safety
Safety Standards Comply with CE and GB4943.1 safety standards
Withstand Voltage I/P-O/P:2KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC/25℃/70% RH
EMC Emission EN61000-3-2:2014/EN61000-3-3:2013
EMC Immunity EN55032:2015/EN55035:2017/60950-1
Others MTBF >299.2k hrs MIL-HDBK-217F(25℃)
Dimension 40*90*100mm (L*W*H)
Packing 0.25Kg
Note

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 

3. Tolerance : includes set up tolerance, line regulation and load regulation. 

4. The output needs to be reduced under the condition of low input voltage, refer to the derating curve chart for details. 

5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may increase of the set up time.

6.Please contact with SMUN customer service for more details.



Previous: 
Next: 

Contact Us

 No. 5, Zhengshun West Road, Xiangyang Industrial Zone, Liushi,Yueqing,Zhejiang,China,325604
+86-13868370609 
+86-0577-62657774 

Quick Links

Quick Links

Copyright © 2024 Zhejiang Ximeng Electronic Technology Co., Ltd. Support by  Leadong   Sitemap
Contact us