LRS-200
SMUN
Description:
The LRS-200 is a high-power, single-output switch-mode power supply from SMUN, a trusted name in the industry. Offering a 200-watt output capacity, this series is designed for applications that require a dependable and efficient DC power source. Key characteristics and benefits of the LRS-200 include:
Applications:
The LRS-200 switch-mode power supply, with its high power, stability, and wide applicability, is widely used in various industries and specific application scenarios. Here are some typical uses of the LRS-200:
LED Lighting Systems:
Provides a constant DC power supply for a variety of indoor and outdoor LED luminaires, light strips, displays, ensuring brightness stability and color consistency in lighting equipment. Its high efficiency helps reduce energy consumption in LED lighting systems, while the wide input voltage makes it easy to adapt to local power environments in different countries and regions.
Industrial Automation:
Powers PLC controllers, servo drives, sensors, actuators, machine vision systems, and other industrial automation equipment, ensuring stable operation of these devices under harsh working conditions. The high reliability and protection features (such as short-circuit protection, overcurrent protection, overvoltage protection, and overtemperature protection) of the LRS-200 are crucial for maintaining continuous operation of industrial production lines.
Communication Equipment:
Supplies stable DC power to base stations, routers, switches, firewalls, remote monitoring devices, and other communication infrastructure, ensuring the stable operation and data transmission reliability of the network system. Its compact design facilitates integration in limited spaces, and the wide range input voltage adapts to grid conditions in different regions.
Medical Devices:
Provides clean and stable power to diagnostic equipment (such as ultrasound and X-ray machines), treatment devices (such as laser therapy devices and ventilators), and laboratory instruments (such as analyzers and centrifuges) in medical settings. It meets the strict power supply requirements of medical equipment, including low ripple, high stability, and high safety.
Security Systems:
Supports surveillance cameras, access control panels, alarm systems, infrared detectors, and other security devices with a reliable power supply, ensuring the round-the-clock stable operation and prompt response capabilities of security systems.
Electric Vehicle Charging Facilities:
In EV charging-related equipment such as charging stations and battery management systems (BMS), the LRS-200 can serve as a control or auxiliary power supply, providing stable power to communication and control circuits during the charging process.
Solar Energy Storage Systems:
In photovoltaic energy storage systems, the LRS-200 can be used to power inverters, battery management systems, and monitoring equipment, ensuring the efficient operation and stable output of the energy storage system.
Audio/Video Equipment:
Provides power for professional sound systems, stage lighting, digital signage, multimedia presentation devices, ensuring high-quality signal transmission and stable operation of audiovisual equipment.
Features:
Universal AC input/Full range
Built-in Emi filter,tiny ripple
Protections:short circuit/overload/over voltage
Cooling by free air convection
43,000 hours of continuous operation at 20℃
100% full load burn-in test
LED indicator for power on
Compliance to IEC/EN60335-1(PD3) and IEC/EN61558-1,2-16 suitable for home appliance
3 years warranty
Model | LRS-200-12 | LRS-200-15 | LRS-200-24 | LRS-200-36 | LRS-200-48 | |
Output | DC Voltage | 12V | 15V | 24V | 36V | 48V |
Current Range | 0-17A | 0-14A | 0-8.4A | 0-5.6A | 0-4.2A | |
Rated Power | 204W | 210W | 201.6W | 201.6W | 201.6W | |
Ripple Noise(Max) | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
Voltage Adj.Range | 10.5~13.8V | 13.5~18V | 21.6~28.8V | 32.4~39.6V | 43.2~52.8V | |
Voltage Tolerance | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Load Regulation | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Set up,Rise time | 1500ms,30ms/230VAC 1500ms,30ms/115VAC(full load) | |||||
Hold up Time | 16ms/230VAC 12ms/115VAC(full load) | |||||
Input | Voltage Range | 85 ~132VAC/170~264VAC selected by switch 240~373VDC(switch on 230VAC) | ||||
Frequency | 47 ~ 63Hz | |||||
Efficiency | 87% | 88% | 89% | 89% | 90% | |
AC Current | 4A/115VAC 2.2A/230VAC | |||||
Inrush Curent | COLD START: 60A/230VAC | |||||
Leakage Current | <2mA / 240VAC | |||||
Protection | Overload | 110 ~ 140% rated output power | ||||
Protection tye:12-36V Hiccup mode,recovers automatically after fault condition is removed | ||||||
Over Voltage | 13.8~16.2V | 18.8~21.8V | 28.8~33.6V | 41.4~48.6V | 55.2~64.8V | |
Protection type : Shut off o/p voltage, re-power on to recover | ||||||
Environment | Working Temperature | -20 ~ +70℃ (Refer to derating curve as datasheet from SMUN) | ||||
Working Humidity | 20 ~ 90% RH non-condensing | |||||
Storage Temp.Humidity | -45 ~ +85℃, 20 ~ 95% RH non-condensing | |||||
Temp.Coefficient | ±0.03%/℃ (0 ~ 50℃) | |||||
Vibration | 10~500Hz,2G 10 min/1 cycle,60min.each X Y Z axes | |||||
Safety | Safety Standards | GB4943.1,EN60950.1 Approved | ||||
Withstand Voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/25℃/70% RH | |||||
EMC Emission | EN61000-3-2:2014/EN61000-3-3:2013 | |||||
EMC Immunity | EN 55032:2015/EN55035:2017/60950-1 | |||||
Others | MTBF | ≥347.5K hrs MIL-HDBK-217F(25℃) | ||||
Dimension | 215*115*30mm (L*W*H) | |||||
Packing | 0.66Kg; 20pcs/13.2Kg/CTN | |||||
Note | 1.All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25℃ of ambient temperature. 2.Ripple noise are measured at 20MHz of bandwidth by using a 12"twisted pair-wire terminated with a 0.1uf and 47uf parallel capacitors. 3.Tolerance includes set up tolerance,line regulation and load regulation. 4.Derating output is required under low input voltage.Please refer to derating curve for details. 5.The power supply should be considered as a part of the components in the system.All EMC tests will test samples on a metal iron plate with a thickness of 1mm,a length of 360mm and width of 36mm. 6.Please contact with SMUN customer service for more details. |
Description:
The LRS-200 is a high-power, single-output switch-mode power supply from SMUN, a trusted name in the industry. Offering a 200-watt output capacity, this series is designed for applications that require a dependable and efficient DC power source. Key characteristics and benefits of the LRS-200 include:
Applications:
The LRS-200 switch-mode power supply, with its high power, stability, and wide applicability, is widely used in various industries and specific application scenarios. Here are some typical uses of the LRS-200:
LED Lighting Systems:
Provides a constant DC power supply for a variety of indoor and outdoor LED luminaires, light strips, displays, ensuring brightness stability and color consistency in lighting equipment. Its high efficiency helps reduce energy consumption in LED lighting systems, while the wide input voltage makes it easy to adapt to local power environments in different countries and regions.
Industrial Automation:
Powers PLC controllers, servo drives, sensors, actuators, machine vision systems, and other industrial automation equipment, ensuring stable operation of these devices under harsh working conditions. The high reliability and protection features (such as short-circuit protection, overcurrent protection, overvoltage protection, and overtemperature protection) of the LRS-200 are crucial for maintaining continuous operation of industrial production lines.
Communication Equipment:
Supplies stable DC power to base stations, routers, switches, firewalls, remote monitoring devices, and other communication infrastructure, ensuring the stable operation and data transmission reliability of the network system. Its compact design facilitates integration in limited spaces, and the wide range input voltage adapts to grid conditions in different regions.
Medical Devices:
Provides clean and stable power to diagnostic equipment (such as ultrasound and X-ray machines), treatment devices (such as laser therapy devices and ventilators), and laboratory instruments (such as analyzers and centrifuges) in medical settings. It meets the strict power supply requirements of medical equipment, including low ripple, high stability, and high safety.
Security Systems:
Supports surveillance cameras, access control panels, alarm systems, infrared detectors, and other security devices with a reliable power supply, ensuring the round-the-clock stable operation and prompt response capabilities of security systems.
Electric Vehicle Charging Facilities:
In EV charging-related equipment such as charging stations and battery management systems (BMS), the LRS-200 can serve as a control or auxiliary power supply, providing stable power to communication and control circuits during the charging process.
Solar Energy Storage Systems:
In photovoltaic energy storage systems, the LRS-200 can be used to power inverters, battery management systems, and monitoring equipment, ensuring the efficient operation and stable output of the energy storage system.
Audio/Video Equipment:
Provides power for professional sound systems, stage lighting, digital signage, multimedia presentation devices, ensuring high-quality signal transmission and stable operation of audiovisual equipment.
Features:
Universal AC input/Full range
Built-in Emi filter,tiny ripple
Protections:short circuit/overload/over voltage
Cooling by free air convection
43,000 hours of continuous operation at 20℃
100% full load burn-in test
LED indicator for power on
Compliance to IEC/EN60335-1(PD3) and IEC/EN61558-1,2-16 suitable for home appliance
3 years warranty
Model | LRS-200-12 | LRS-200-15 | LRS-200-24 | LRS-200-36 | LRS-200-48 | |
Output | DC Voltage | 12V | 15V | 24V | 36V | 48V |
Current Range | 0-17A | 0-14A | 0-8.4A | 0-5.6A | 0-4.2A | |
Rated Power | 204W | 210W | 201.6W | 201.6W | 201.6W | |
Ripple Noise(Max) | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
Voltage Adj.Range | 10.5~13.8V | 13.5~18V | 21.6~28.8V | 32.4~39.6V | 43.2~52.8V | |
Voltage Tolerance | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Load Regulation | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Set up,Rise time | 1500ms,30ms/230VAC 1500ms,30ms/115VAC(full load) | |||||
Hold up Time | 16ms/230VAC 12ms/115VAC(full load) | |||||
Input | Voltage Range | 85 ~132VAC/170~264VAC selected by switch 240~373VDC(switch on 230VAC) | ||||
Frequency | 47 ~ 63Hz | |||||
Efficiency | 87% | 88% | 89% | 89% | 90% | |
AC Current | 4A/115VAC 2.2A/230VAC | |||||
Inrush Curent | COLD START: 60A/230VAC | |||||
Leakage Current | <2mA / 240VAC | |||||
Protection | Overload | 110 ~ 140% rated output power | ||||
Protection tye:12-36V Hiccup mode,recovers automatically after fault condition is removed | ||||||
Over Voltage | 13.8~16.2V | 18.8~21.8V | 28.8~33.6V | 41.4~48.6V | 55.2~64.8V | |
Protection type : Shut off o/p voltage, re-power on to recover | ||||||
Environment | Working Temperature | -20 ~ +70℃ (Refer to derating curve as datasheet from SMUN) | ||||
Working Humidity | 20 ~ 90% RH non-condensing | |||||
Storage Temp.Humidity | -45 ~ +85℃, 20 ~ 95% RH non-condensing | |||||
Temp.Coefficient | ±0.03%/℃ (0 ~ 50℃) | |||||
Vibration | 10~500Hz,2G 10 min/1 cycle,60min.each X Y Z axes | |||||
Safety | Safety Standards | GB4943.1,EN60950.1 Approved | ||||
Withstand Voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/25℃/70% RH | |||||
EMC Emission | EN61000-3-2:2014/EN61000-3-3:2013 | |||||
EMC Immunity | EN 55032:2015/EN55035:2017/60950-1 | |||||
Others | MTBF | ≥347.5K hrs MIL-HDBK-217F(25℃) | ||||
Dimension | 215*115*30mm (L*W*H) | |||||
Packing | 0.66Kg; 20pcs/13.2Kg/CTN | |||||
Note | 1.All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25℃ of ambient temperature. 2.Ripple noise are measured at 20MHz of bandwidth by using a 12"twisted pair-wire terminated with a 0.1uf and 47uf parallel capacitors. 3.Tolerance includes set up tolerance,line regulation and load regulation. 4.Derating output is required under low input voltage.Please refer to derating curve for details. 5.The power supply should be considered as a part of the components in the system.All EMC tests will test samples on a metal iron plate with a thickness of 1mm,a length of 360mm and width of 36mm. 6.Please contact with SMUN customer service for more details. |