Availability: | |
---|---|
Quantity: | |
SMV-60
SMUN
A 60W constant voltage waterproof driver is a power supply device specifically designed for lighting fixtures and other electrical equipment that need to work in damp or outdoor environments. It is primarily used to provide a stable voltage output, ensuring that connected devices function properly. Here is a summary of its main functions and roles:
Constant Voltage Output: Regardless of variations in input voltage, a 60W constant voltage waterproof driver can maintain a fixed output voltage. This is crucial for lamps that require a stable power supply, helping to avoid issues like flickering or reduced lifespan due to voltage fluctuations.
Waterproof Functionality: This driver comes with waterproof design, typically featuring a specific protection rating IP67, enabling it to operate in damp conditions or even direct contact with water without being damaged. This characteristic is particularly suitable for outdoor lighting applications, such as street lighting, landscape lighting, and pool lighting.
Durability: To withstand various weather conditions outdoors, a 60W constant voltage waterproof driver is often built with robust casing materials, and its internal components are treated to resist moisture and dust, thereby increasing its durability.
Safety: The waterproof design enhances product safety, effectively preventing short circuits and electric shocks, especially in situations where water exposure is possible.
Wide Range of Applications: Beyond outdoor lighting, this driver is also applicable to other electrical devices that require waterproof features, such as billboards and LED displays.
Efficient Energy Conversion: High-efficiency 60W constant voltage waterproof drivers achieve higher energy conversion rates, meaning they can minimize energy loss and improve the overall efficiency of energy utilization.
Specification
Model | SMV-60-12 | SMV-60-15 | SMV-60-24 | SMV-60-36 | SMV-60-48 | |
Output | DC voltage | 12V | 15V | 24V | 36V | 48V |
Rated current | 5A | 4A | 2.5A | 1.7A | 1.3A | |
Current range | 0-5.0A | 0-4.0A | 0-2.5A | 0-1.7A | 0-1.3A | |
Rated power | 60W | 60W | 60W | 61.2W | 62.4W | |
Ripple&noise | 50mVp-p | 50mVp-p | 80mVp-p | 100mVp-p | 100mVp-p | |
Voltage tolerance | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Line regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Load regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Set up,rise time | 200ms,50ms,30ms | |||||
Hold up time(Typ.) | 30ms/230VAC | |||||
Input | Voltage range | 85~264VAC or 120~373VDC | ||||
Frequency | 47 ~ 63Hz | |||||
Efficiency | 82% | 82% | 84% | 84% | 85% | |
AC current | 0.8A/230V | |||||
Inrush current | Cold start: 45A/230V | |||||
Leakage current | <1.5mA/240VAC | |||||
Protection | Overload | Rated output power 105%~135% start overload protection | ||||
Protection type:hiccup mode,auto-recovery after fault condition is removed | ||||||
Over voltage | Rater output power 135%~150% start over voltage protection | |||||
Protection type:Shut down o/p voltage, re-power on to recover | ||||||
Over temperature | When temperature of transistor inner node is over 105℃,start over temperature protection | |||||
Protection type:Shut down o/p voltage, re-power on to recover | ||||||
Environment | Working temperature | -10℃~+60℃ | ||||
Working humidity | 20-90%RH | |||||
Storage temp,humidity | -20~+85℃,20%-90%RH | |||||
Temp.coefficient | ±0.03%℃(0-50℃) | |||||
Vibration | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | |||||
Safety & EMC |
Safety standards | Compliance to:CE and GB4943.1 safety standards | ||||
Withstand voltage | I/P-O/P:1.5KVAC 1minute I/P-FG:1.5KVAC 1minute O/P-PG:0.5KVAC 1minute | |||||
Isolation resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||
EMC emission | EN61000-3-2:2014/EN61000-3-3:2013 | |||||
EMC immunity | EN 55032:2015/EN55035:2017/60950-1 | |||||
Others | MTBF | ≥327.9K hrs MIL-HDBK-217F(25℃) | ||||
Size | L190*W49*H34mm | |||||
Packing | 0.55KG | |||||
Note | 1. All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25℃ of ambient temperature. 2. Ripple&noise are measured at 20MHz of bandwidth by using a 12 "twisted pair -wire terminated with a 0.1uf and 47uf parallel capacitors. 3. Tolerance:includes set up tolerance,line regulation and load regulation. 4. Derating output is required under low input voltage. Please refer to the derating curve for details. 5. The power supply should be considered as a part of the components in the system. All EMC tests will test the test samples on a metal iron plate with a thickness of 1mm, a length of 360mm * width of 360mm. |
|||||
A 60W constant voltage waterproof driver is a power supply device specifically designed for lighting fixtures and other electrical equipment that need to work in damp or outdoor environments. It is primarily used to provide a stable voltage output, ensuring that connected devices function properly. Here is a summary of its main functions and roles:
Constant Voltage Output: Regardless of variations in input voltage, a 60W constant voltage waterproof driver can maintain a fixed output voltage. This is crucial for lamps that require a stable power supply, helping to avoid issues like flickering or reduced lifespan due to voltage fluctuations.
Waterproof Functionality: This driver comes with waterproof design, typically featuring a specific protection rating IP67, enabling it to operate in damp conditions or even direct contact with water without being damaged. This characteristic is particularly suitable for outdoor lighting applications, such as street lighting, landscape lighting, and pool lighting.
Durability: To withstand various weather conditions outdoors, a 60W constant voltage waterproof driver is often built with robust casing materials, and its internal components are treated to resist moisture and dust, thereby increasing its durability.
Safety: The waterproof design enhances product safety, effectively preventing short circuits and electric shocks, especially in situations where water exposure is possible.
Wide Range of Applications: Beyond outdoor lighting, this driver is also applicable to other electrical devices that require waterproof features, such as billboards and LED displays.
Efficient Energy Conversion: High-efficiency 60W constant voltage waterproof drivers achieve higher energy conversion rates, meaning they can minimize energy loss and improve the overall efficiency of energy utilization.
Specification
Model | SMV-60-12 | SMV-60-15 | SMV-60-24 | SMV-60-36 | SMV-60-48 | |
Output | DC voltage | 12V | 15V | 24V | 36V | 48V |
Rated current | 5A | 4A | 2.5A | 1.7A | 1.3A | |
Current range | 0-5.0A | 0-4.0A | 0-2.5A | 0-1.7A | 0-1.3A | |
Rated power | 60W | 60W | 60W | 61.2W | 62.4W | |
Ripple&noise | 50mVp-p | 50mVp-p | 80mVp-p | 100mVp-p | 100mVp-p | |
Voltage tolerance | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Line regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Load regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Set up,rise time | 200ms,50ms,30ms | |||||
Hold up time(Typ.) | 30ms/230VAC | |||||
Input | Voltage range | 85~264VAC or 120~373VDC | ||||
Frequency | 47 ~ 63Hz | |||||
Efficiency | 82% | 82% | 84% | 84% | 85% | |
AC current | 0.8A/230V | |||||
Inrush current | Cold start: 45A/230V | |||||
Leakage current | <1.5mA/240VAC | |||||
Protection | Overload | Rated output power 105%~135% start overload protection | ||||
Protection type:hiccup mode,auto-recovery after fault condition is removed | ||||||
Over voltage | Rater output power 135%~150% start over voltage protection | |||||
Protection type:Shut down o/p voltage, re-power on to recover | ||||||
Over temperature | When temperature of transistor inner node is over 105℃,start over temperature protection | |||||
Protection type:Shut down o/p voltage, re-power on to recover | ||||||
Environment | Working temperature | -10℃~+60℃ | ||||
Working humidity | 20-90%RH | |||||
Storage temp,humidity | -20~+85℃,20%-90%RH | |||||
Temp.coefficient | ±0.03%℃(0-50℃) | |||||
Vibration | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | |||||
Safety & EMC |
Safety standards | Compliance to:CE and GB4943.1 safety standards | ||||
Withstand voltage | I/P-O/P:1.5KVAC 1minute I/P-FG:1.5KVAC 1minute O/P-PG:0.5KVAC 1minute | |||||
Isolation resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||
EMC emission | EN61000-3-2:2014/EN61000-3-3:2013 | |||||
EMC immunity | EN 55032:2015/EN55035:2017/60950-1 | |||||
Others | MTBF | ≥327.9K hrs MIL-HDBK-217F(25℃) | ||||
Size | L190*W49*H34mm | |||||
Packing | 0.55KG | |||||
Note | 1. All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25℃ of ambient temperature. 2. Ripple&noise are measured at 20MHz of bandwidth by using a 12 "twisted pair -wire terminated with a 0.1uf and 47uf parallel capacitors. 3. Tolerance:includes set up tolerance,line regulation and load regulation. 4. Derating output is required under low input voltage. Please refer to the derating curve for details. 5. The power supply should be considered as a part of the components in the system. All EMC tests will test the test samples on a metal iron plate with a thickness of 1mm, a length of 360mm * width of 360mm. |
|||||